Use Base Table (-basetable) with TableRange Size (-tablerangesize) to specify the range of tables for which you want to collect statistics.
Operating system and syntax
UNIX / Windows
-basetable n
Use with
Maximum value
Minimum value
Single-user default
Multi-user default
Database Server
32765
-32765
n
The starting table number in the range of tables for which you want to track access statistics.
Access to the statistics is handled through the Virtual System Tables (VSTs). Table statistics are stored in the _TableStat VST. To obtain table numbers, use the following ABL code:
FOR EACH _file:
  DISPLAY _file._file-num _file._file-name.
END.
Running the preceding code results in the following output: