Try OpenEdge Now
skip to main content
Troubleshooting Guide
BPM WebFlow : BPM WebFlow log file error messages
 

BPM WebFlow log file error messages

The following table lists BPM WebFlow error messages.

Error messages

Table 10. BPM WebFlow log file error messages
Error
Possible cause(s)
Resolution/Workaround
BizSolo_ERR_001
Initializing BizSoloAPI error.
Verify bpmwebflow.conf file is present in the OEBPS_HOME\conf directory and review the file parameters. Verify parameters in CLASSPATH.
BizSolo_ERR_002
An error occurred within getBPMWebFlowFileList().
Call Progress OpenEdge Technical Support.
BizSolo_ERR_003
An error occurred within getBPMWebFlowAppList().
Call Progress OpenEdge Technical Support.
BizSolo_ERR_004
An error occurred within getBPMWebFlowAppURL() for {0}.
Call Progress OpenEdge Technical Support.
BizSolo_ERR_005
An error occurred within installBPMWebFlowApp() for {0}.
Call Progress OpenEdge Technical Support.
BizSolo_ERR_006
An error occurred within uninstallBPMWebFlowApp() for {0}.
Call Progress OpenEdge Technical Support.
BizSolo_ERR_007
Cannot find application URL for {0}. Not able to construct URL with supplied application name.
Verify that the application {0} is installed. If it is, call Progress OpenEdge Technical Support.
BizSolo_ERR_008
An error occurred while attempting to generate JSP files for {0}.
Check the error log file for additional information.
BizSolo_ERR_009
An error occurred while attempting to save BPM WebFlow serialization file.
Call Progress OpenEdge Technical Support.
BizSolo_ERR_010
An error occurred while attempting to load BPM WebFlow serialization file.
Call Progress OpenEdge Technical Support.
BizSolo_ERR_012
An error occurred while initializing BPM WebFlow.
Verify bpmworkflow.conf file is present in the OEBPS_HOME\conf directory and review the file parameters. Verify parameters in CLASSPATH.
BizSolo_ERR_014
An error occurred while attempting to save BPM WebFlow serialization file.
Call Progress OpenEdge Technical Support.
BizSolo_ERR_015
An error occurred while attempting to load BPM WebFlow serialization file.
Call Progress OpenEdge Technical Support.
BizSolo_ERR_016
Can not find BP Server {0}.
The BP Server is down, or the incorrect machine name is specified for the BP Server.
BizSolo_ERR_017
An error occurred while initializing PAKBizSoloBean.
Verify bpmwebflow.conf file is present in the OEBPS_HOME\conf directory and review the file parameters. Verify parameters in CLASSPATH.
BizSolo_ERR_018
An error occurred while creating a BP Server process instance. A BP Server error.
See the bpserver.log file for additional information.
BizSolo_ERR_019
An error occurred while completing BP Server workitem. A BP Server error.
See the bpserver.log file for additional information.
BizSolo_ERR_023
An error occurred while attempting to uninstall application {0}.
The named application is not installed, a backup already exists, or a backup file cannot be created.
BizSolo_ERR_025
An error occurred while attempting to disconnect from BP Server. Communication error with BP Server.
Verify the BP Server is running. Start the BP Server and run the application again.
BizSolo_ERR_026
Cannot find the settings file: {0}.
Verify bpmebflow.conf in CLASSPATH.
BizSolo_ERR_027
Application {0} is not installed! (Information message)
Install the application {0}.
BizSolo_ERR_028
Cannot create a backup for application {0}. Backup already exists.
Call Progress OpenEdge Technical Support.
BizSolo_ERR_029
Invalid dataslot name: {0}. Choices: {1}. Valid names provided in log file.
Call Progress OpenEdge Technical Support.
BizSolo_ERR_031
Invalid page type {0} found while processing workstep {1}.
Call Progress OpenEdge Technical Support.
BizSolo_ERR_032
Invalid link found between source page {0} and destination page {1}.
Call Progress OpenEdge Technical Support.
BizSolo_ERR_033
ProcesGenerator@getAttrValue: null node found.
Call Progress OpenEdge Technical Support.
BizSolo_ERR_034
ProcesGenerator@getAttrValue: null attribute found.
Call Progress OpenEdge Technical Support.
BizSolo_ERR_035
ProcesGenerator@getAttrValue: invalid node type {1}.
Call Progress OpenEdge Technical Support.
BizSolo_ERR_036
Attribute {0} does not exist in node {1}. error in parsing xml file.
Call Progress OpenEdge Technical Support.
BizSolo_ERR_038
WARNING: This error occurs during XML parsing.
Regenerate the process template. If the problem persists, call Progress OpenEdge Technical Support.
BizSolo_ERR_039
ERROR: This error occurs during XML parsing.
Regenerate the process template. If the problem persists, call Progress OpenEdge Technical Support.
BizSolo_ERR_040
FATAL ERROR: ProcesGenerator will stop. This error occurs during XML parsing.
Regenerate the process template. If the problem persists, call Progress OpenEdge Technical Support.
BizSolo_DBG_043
Append attribute name={0}, Value={1} to dataslot {3}.
See error log file for additional information.
BizSolo_ERR_044
DS@getJSP: Found invalid input dataslot type ({0}, {1}).
Call Progress OpenEdge Technical Support.
BizSolo_ERR_045
DS@setJSP: Found invalid output dataslot type ({0}, {1}).
Call Progress OpenEdge Technical Support.
BizSolo_ERR_046
DS@getHTML: Found invalid input dataslot type ({0}, {1}).
Call Progress OpenEdge Technical Support.
BizSolo_ERR_047
GenericList@getItem: Cannot find a tag with index={0}.
Call Progress OpenEdge Technical Support.
BizSolo_ERR_048
Error writing @include directive for file {0} in file {1}.JSP.
Call Progress OpenEdge Technical Support.
BizSolo_ERR_049
JSPGenerator@write_jspinit: Invalid DS Type: {0}.
Call Progress OpenEdge Technical Support.
BizSolo_ERR_050
JSPGenerator@declare_DS: Dataslot {0} has an invalid type: {1}.
Call Progress OpenEdge Technical Support.
BizSolo_ERR_051
JSPGenerator@write_jsp_getParam: Found invalid (null) input dataslot: {0} in page: {1}.
Call Progress OpenEdge Technical Support.
BizSolo_ERR_052
JSPGenerator@write_jsp_getParam2: Found invalid (null) input dataslot: {0} in page: {1}.
Call Progress OpenEdge Technical Support.
BizSolo_ERR_053
JSPGenerator@write: invalid file descriptor.
Call Progress OpenEdge Technical Support.
BizSolo_ERR_054
JSPGenerator@write: null string passed as parameter.
Call Progress OpenEdge Technical Support.
BizSolo_ERR_055
JSPGenerator@write: Unknown error while generating an application file.
Call Progress OpenEdge Technical Support.
BizSolo_ERR_056
Error: Link {0} has an unknown type: {1}.
Call Progress OpenEdge Technical Support.
BizSolo_ERR_057
Link@setJSP: invalid call.
Call Progress OpenEdge Technical Support.
BizSolo_ERR_058
Link@getHTML: invalid call.
Call Progress OpenEdge Technical Support.
BizSolo_ERR_059
Link@setHTML: invalid call.
Call Progress OpenEdge Technical Support.
BizSolo_ERR_060
Error: Attempt to set an incorrect type ({0}) for link {1}.
Call Progress OpenEdge Technical Support.
BizSolo_ERR_061
Error: Attempt to set an incorrect filetype ({0}) for page {1}.
Call Progress OpenEdge Technical Support.
BizSolo_ERR_062
Error: Attempt to set an incorrect type ({0}) for page {1}.
Call Progress OpenEdge Technical Support.
BizSolo_ERR_063
Page@addDSI: null input dataslot.
Call Progress OpenEdge Technical Support.
BizSolo_ERR_064
Page@addDSO: null output dataslot.
Call Progress OpenEdge Technical Support.
BizSolo_ERR_065
Page@addInitDS: null dataslot.
Call Progress OpenEdge Technical Support.
BizSolo_MSG_066
Page: {0}, Filename: {1} (Information message).
BizSolo_MSG_067
Hello, this is BPM WebFow build {0} (Information message).
BizSolo_ERR_068
Error at GenericAction@getPropObj: Unable to get properties form external performer.
See error log for additional information.
BizSolo_ERR_069
Error at GenericAction@getPropString: Unable to get properties form external performer.
See error log for additional information.
BizSolo_ERR_070
Error at GenericAction@setPropLong: Unable to get properties form external performer.
See error log for additional information.
BizSolo_ERR_071
Error at GenericAction@getPropLong: Unable to get properties form external performer.
See error log for additional information.
BizSolo_ERR_072
Error at GenericAction@setPropDouble: Unable to get properties form external performer.
See error log for additional information.
BizSolo_ERR_073
Error at GenericAction@getPropDouble: Unable to get properties form external performer.
See error log for additional information.
BizSolo_ERR_074
Email EP @ commit: Error while sending email. Unable to communicate with email server, or wrong email server name provided in external performer.
Verify that oebps.conf has the correct configuration. If it does, check the mail server status.
BizSolo_ERR_075
Cannot create backup information (timestamp file) for application {0}. Operating system-level error.
Disk is full.
BizSolo_MSG_076
Creating backup directory {0} (Information message).
BizSolo_MSG_077
Saving file: {0} (customized) (Information message).
BizSolo_MSG_078
Deleting file {0} (unchanged). (Information message.)
BizSolo_MSG_079
The following customized file(s) were saved under {0} : {1}. Please make sure that you incorporate changes from the saved files into the newly generated ones (information message).
BizSolo_MSG_080
Please check BPM WebFlow log file {0}.
BizSolo_ERR_081
Incorrect log level. Use: 1=ERROR, 2=WARNING, 3=NOTICE(DEFAULT), 4=INFO, 5=DEBUG.
Correct the log level.
BizSolo_ERR_082
GenericAction@setPropBoolean(String,String)
See error log for additional information.
BizSolo_ERR_083
GenericAction@getPropBoolean(String)
See error log for additional information.
BizSolo_ERR_084
GenericAction@getPropBoolean(int)
See error log for additional information.
BizSolo_ERR_085
GenericAction@getPropBSObject(int)
See error log for additional information.
BizSolo_WRN_088
Missing/incorrect parameter specification for {0} in bpmworkflow.conf file. Defaulting to : {1}.
Make sure this is what you expected or put the right value for this parameter in the conf file.
BizSolo_ERR_090
Failed to save the state of workitem to BP Server.
Verify that the BP Server is running.
BizSolo_ERR_091
Failed to reassign workstep.
Verify that the BP Server is running.
BizSolo_ERR_094
Null value found in the following BS object: {0}.
Not an error, check the application dataslot values.
BizSolo_ERR_096
Error while locating {0} method of the {1} class.
Make sure the class {1} exists.
BizSolo_ERR_097
Error while invoking {0} method of the {1} class.
Make sure the class {1} exists.
BizSolo_ERR_098
Unable to locate filename: {0}
The application {0} does not exist under OEBPS_HOME\BPMWebFlow.
BizSolo_ERR_099
Unable to load file {0}.
Please make sure you have it in your CLASSPATH.
BizSolo_ERR_100
Unable to find {0} in {1} or in {2}. Please make sure you have a file with this name at least in {2} directory
Call Progress OpenEdge Technical Support.
BizSolo_ERR_101
Null/empty value for Link name: {0}, type: {1}. Please use a value for this link.
Image files used in the application do not exist.
BizSolo_WRN_104
Null parameter name in setDefault(). You may get an error!
Check and correct any previous WRN_102 message then reinstall this application.
BizSolo_ERR_105
Null/empty performer class name for Adapter : {0}.
Provide performer class name in the Progress Developer Studio for OpenEdge then reinstall this application.
BizSolo_ERR_106
Null/empty workstep name. Unable to continue.
Provide workstep name in the Progress Developer Studio for OpenEdge, then reinstall this application.
BizSolo_MSG_107
Attempting to create pages for application : {0}.
BizSolo_ERR_108
Null pagelist. Unable to validate the data read from the XML file.
Call Progress OpenEdge Technical Support.
BizSolo_ERR_109
Null page in application pagelist. Unable to validate the data read from the XML file.
Call Progress OpenEdge Technical Support.
BizSolo_ERR_110
Cannot find any link out of page {0}. You may not be able to complete the workflow as you cannot move on to the next page.
Check your process definition for a missing connection out of the above mentioned page.