Try OpenEdge Now
skip to main content
Clustering Guide
After setting up BusinessManager cluster : Verifying servers : Verifying BPM Events server
 

Verifying BPM Events server

To verify BPM Events server status on one of the nodes of the cluster:
1. Start the BPM Events Admin utility by executing startBPMEventsAdmin.sh/cmd from <OEBPS_HOME>/bin location.
2. After starting the BPM Events Admin utility, use it as follows:
============ Host : sys128.tdiinc.com ============
0) Back
1) Server Monitor
2) Loader
3) Rule Manager
4) Persistent Structure Monitor
5) Event Manager
6) Scheduler
7) File Manager
8) JMS
Enter your selection ( 0 - 8 ) : 1
============ Server Monitor ============
0) Back
1) Print Status
2) Suspend
3) Resume
4) Stop
5) Start
6) Start Monitor
7) Stop Monitor
Enter your selection ( 0 - 7 ) : 1
No. of Nodes: 2
Node: sys128.tdiinc.com
BPM Events state: Stopped
Monitor state: Running
Node: sys120.tdiinc.com
BPM Events state: Running
Monitor state: Running
EventsToBeProcessed: 0
State: run
FreeHeapMemory: 225234192
EventsProcessed: 127
HeapMemoryAllocated: 266076160
If BPM Events server is running only on one of the nodes and BPM Events monitor is running on all the other nodes, then it confirms that the BPM Events cluster is set up correctly.