Try OpenEdge Now
skip to main content
Database Diagnostic Data Collection
Diagnostic startup parameters : Diagnostic event level (-diagEvtLevel)
 

Diagnostic event level (-diagEvtLevel)

Use Diagnostic event level (-diagEvtLevel) to specify the "level" of diagnostic data to collect.
Operating system and syntax
UNIX / Windows
-diagEvtLevel n
Use with
Maximum value
Minimum value
Single-user default
Multi-user default
Database Server
15
-15
0
n
An integer in the range of -15 to 15.
The following table describes the level settings.
Event Level (+/-)
Data collected
Spawn process
0
None
No
1
Summary data
No
2
Summary Data
Detailed Data
No
3
Summary Data
Detailed Data
Protrace collection
No
4
None
Yes
5
Summary data
(1+4)
Yes
6
Summary data
Detailed Data
(2+4)
Yes
7
Summary data
Detailed Data
Protrace collection
(3+4)
Yes
8
Record data of all other enabled events
No
9
Summary Data
Record data of all other enabled events
(1+8)
No
10
Summary Data
Detailed Data
Record data of all other enabled events
(2+8)
No
11
Summary Data
Detailed Data
Protrace collection
Record data of all other enabled events
(3+8)
No
12
Record data of all other enabled events
Yes
13
Summary data
Record data of all other enabled events
(1+12)
Yes
14
Summary data
Detailed Data
Record data of all other enabled events
(2+12)
Yes
15
Summary data
Detailed Data
Protrace collection
Record data of all other enabled events
(3+12)
Yes
The protrace collection is only available on UNIX.