| 
        Attribute
        | 
        Description
        | 
| 
        linelimit=numberofchars
        | 
        Sets the maximum number of characters that DataDirect Spy logs on a single line.
        
        The default is 0 (no maximum limit).
        | 
| 
        load=classname
        | 
        Loads the driver specified by classname.
        | 
| 
        log=(file)filename
        | 
        Directs logging to the file specified by filename.
        
        For Windows, if coding a path to the log file in a Java string, the backslash character (\) must be preceded by the Java escape character, a backslash. For example: log=(file)C:\\temp\\spy.log;logIS=yes;logTName=yes.
        | 
| 
        log=(filePrefix)file_prefix
        | 
        Directs logging to a file prefixed by file_prefix. The log file is named file_prefixX.log
        
        where:
        
        X
        
        is an integer that increments by 1 for each connection on which the prefix is specified.
        
        For example, if the attribute log=(filePrefix) C:\\temp\\spy_ is specified on multiple connections, the following logs are created:
        
        C:\temp\spy_1.log
         C:\temp\spy_2.log C:\temp\spy_3.log ... 
        If coding a path to the log file in a Java string, the backslash character (\) must be preceded by the Java escape character, a backslash. For example: log=(filePrefix)C:\\temp\\spy_;logIS=yes;logTName=yes.
        | 
| 
        log=System.out
        | 
        Directs logging to the Java output standard, System.out.
        | 
| 
        logIS={yes | no | nosingleread}
        | 
        Specifies whether DataDirect Spy logs activity on InputStream and Reader objects.
        
        When logIS=nosingleread, logging on InputStream and Reader objects is active; however, logging of the single-byte read InputStream.read or single-character Reader.read is suppressed to prevent generating large log files that contain single-byte or single character read messages.
        
        The default is no.
        | 
| 
        logLobs={yes | no}
        | 
        Specifies whether DataDirect Spy logs activity on BLOB and CLOB objects.
        | 
| 
        logTName={yes | no}
        | 
        Specifies whether DataDirect Spy logs the name of the current thread.
        
        The default is no.
        | 
| 
        timestamp={yes | no}
        | 
        Specifies whether a timestamp is included on each line of the DataDirect Spy log. The default is yes.
        |